Liyu Power LY1200 Gas Engine Power Plant

1,100 kW

For installation in the machine room

«SP Trade» offers the opportunity to purchase a Liyu Power LY1200 gas piston power plant (GPU) from one of the leading Asian manufacturers. This reliable equipment, designed for electricity generation without heat recovery, is optimally suited for establishing autonomous power supply systems.

Key Features of Gas-Powered LY1200

Number of cylinders

Number of cylinders

12

12

Electric Power

Electric Power

1,100 kW

1,100 kW

Thermal power

Thermal power

1,200 kW

1,200 kW

Electrical efficiency:

Electrical efficiency:

41.0%

41.0%

Overall Efficiency:

Overall Efficiency:

86.1%

86.1%

Type of gas:

Type of gas:

natural

natural

Dimensions (L x W x H):

Dimensions (L x W x H):

5300/1700/2300 mm

5300/1700/2300 mm

Net weight:

Net weight:

13,000 kg

13,000 kg

Benefits of a 1 MW GPU

The 1000 kW Mini-CHP combines high performance, cost-effectiveness, and environmental friendliness. Gas power plants are becoming a popular choice among businesses due to the following advantages:



  • 1 MW Power. The 1000 kW gas engine unit provides sufficient energy output for industrial enterprises, utility facilities, or farms.

  • Reliability. The generator of the gas engine unit is designed for long-term operation with minimal maintenance costs.

  • Eco-friendliness. Operating on natural gas or biogas reduces CO₂ emissions. This makes the gas engine unit advantageous for meeting environmental standards.

  • Fuel Availability. Natural gas is widely available and cheaper compared to other types of fuel.

  • Scalability. The possibility to connect multiple generators in sections to increase power capacity.

Gas engine power plants have high profitability. You can calculate the payback period using our online calculator.



Why it's beneficial to buy a 1000 kW GPU from us

Why it's beneficial to buy a 1000 kW GPU from us

Why it's beneficial to buy a 1000 kW GPU from us

SP Trade Company offers favorable conditions for purchasing gas piston power plants at 1000 kW. We offer:



  • competitive prices for mini-CHPs at 1000 kW;

  • assistance in selecting a GPP tailored to individual needs;

  • organization of installation and commissioning;

  • warranty and post-warranty service of the gas piston unit.

The Liyu Power LY1200 gas power plant is a solution that allows you to optimize your enterprise's power supply. The 1 MW GPP combines high power, reliability, and low operating costs. Contact us at +7 985 460 19 97, +7 985 460 11 60 to find out the exact price, purchase a 1000 kW gas piston unit, and clarify delivery terms.



SP Trade Company offers favorable conditions for purchasing gas piston power plants at 1000 kW. We offer:



  • competitive prices for mini-CHPs at 1000 kW;

  • assistance in selecting a GPP tailored to individual needs;

  • organization of installation and commissioning;

  • warranty and post-warranty service of the gas piston unit.

The Liyu Power LY1200 gas power plant is a solution that allows you to optimize your enterprise's power supply. The 1 MW GPP combines high power, reliability, and low operating costs. Contact us at +7 985 460 19 97, +7 985 460 11 60 to find out the exact price, purchase a 1000 kW gas piston unit, and clarify delivery terms.



SP Trade Company offers favorable conditions for purchasing gas piston power plants at 1000 kW. We offer:



  • competitive prices for mini-CHPs at 1000 kW;

  • assistance in selecting a GPP tailored to individual needs;

  • organization of installation and commissioning;

  • warranty and post-warranty service of the gas piston unit.

The Liyu Power LY1200 gas power plant is a solution that allows you to optimize your enterprise's power supply. The 1 MW GPP combines high power, reliability, and low operating costs. Contact us at +7 985 460 19 97, +7 985 460 11 60 to find out the exact price, purchase a 1000 kW gas piston unit, and clarify delivery terms.



Liyu Power LY1200

Liyu Power LY1200

Liyu Power LY1200

Liyu Power GPU Model

LY1200 (LY1200GL-T, LY1200GM-T, LY1200GH-T)

Liyu Power GPU Model

LY1200 (LY1200GL-T, LY1200GM-T, LY1200GH-T)

Liyu Power GPU Model

LY1200 (LY1200GL-T, LY1200GM-T, LY1200GH-T)

Engine model

LY12V170-T

Engine model

LY12V170-T

Engine model

LY12V170-T

Electric Power

1,100 kW

Electric Power

1,100 kW

Electric Power

1,100 kW

Thermal power

1,200 kW

Thermal power

1,200 kW

Thermal power

1,200 kW

Electrical Efficiency

41.0%

Electrical Efficiency

41.0%

Electrical Efficiency

41.0%

Overall efficiency

86.1%

Overall efficiency

86.1%

Overall efficiency

86.1%

Voltage

0.4/6.3/10.5 kV

Voltage

0.4/6.3/10.5 kV

Voltage

0.4/6.3/10.5 kV

Fuel consumption at 100%, LHV – 9.3

288 Nm³/hr

Fuel consumption at 100%, LHV – 9.3

288 Nm³/hr

Fuel consumption at 100%, LHV – 9.3

288 Nm³/hr

Type of Fuel

Natural gas (GOST 5542-2014), APG, BIO, landfill gas, etc.

Type of Fuel

Natural gas (GOST 5542-2014), APG, BIO, landfill gas, etc.

Type of Fuel

Natural gas (GOST 5542-2014), APG, BIO, landfill gas, etc.

Specific oil consumption

≤0.2 g/kWh

Specific oil consumption

≤0.2 g/kWh

Specific oil consumption

≤0.2 g/kWh

Service Interval

2,000 m/h

Service Interval

2,000 m/h

Service Interval

2,000 m/h

Service life until major overhaul

64,000 hours

Service life until major overhaul

64,000 hours

Service life until major overhaul

64,000 hours

Dimensions (L x W x H)

5300/1700/2300 mm

Dimensions (L x W x H)

5300/1700/2300 mm

Dimensions (L x W x H)

5300/1700/2300 mm

Net weight

13,000 kg

Net weight

13,000 kg

Net weight

13,000 kg

Additional Technical Specifications

Additional Technical Specifications

Additional Technical Specifications

4-valve individual head for each cylinder of the gas engine unit.

4-valve individual head for each cylinder of the gas engine unit.

4-valve individual head for each cylinder of the gas engine unit.

Two-stage cooling of the gas-air mixture.

Two-stage cooling of the gas-air mixture.

Two-stage cooling of the gas-air mixture.

The content of harmful substances in exhaust gases is regulated by adjusting the temperature in the combustion chamber.

The content of harmful substances in exhaust gases is regulated by adjusting the temperature in the combustion chamber.

The content of harmful substances in exhaust gases is regulated by adjusting the temperature in the combustion chamber.

The positioning of the spark plugs is in the center of the cylinder heads within a cooled sleeve.

The positioning of the spark plugs is in the center of the cylinder heads within a cooled sleeve.

The positioning of the spark plugs is in the center of the cylinder heads within a cooled sleeve.

NOx Emissions: ≤500 mg/Nm³ (2 g/kWh)

NOx Emissions: ≤500 mg/Nm³ (2 g/kWh)

NOx Emissions: ≤500 mg/Nm³ (2 g/kWh)

Question and Answer

What is the number of personnel required to service a 1000 kW GPU?

What is the number of personnel required to service a 1000 kW GPU?

What is the number of personnel required to service a 1000 kW GPU?

Do you perform supervision and commissioning work?

Do you perform supervision and commissioning work?

Do you perform supervision and commissioning work?

Can a 1 MW gas turbine process associated gas with hydrogen sulfide content of up to 5–6%?

Can a 1 MW gas turbine process associated gas with hydrogen sulfide content of up to 5–6%?

Can a 1 MW gas turbine process associated gas with hydrogen sulfide content of up to 5–6%?

Product Brochure

Take advantage of Liyu gas piston units and achieve: reduced costs for electricity and thermal energy, ensuring the energy independence of the enterprise.

Product Brochure

Take advantage of Liyu gas piston units and achieve: reduced costs for electricity and thermal energy, ensuring the energy independence of the enterprise.

Product Brochure

Take advantage of Liyu gas piston units and achieve: reduced costs for electricity and thermal energy, ensuring the energy independence of the enterprise.

Advantages

Advantages of Gas-Piston Power Plants

80x

Carbon footprint

We actively embrace new ideas and technologies, positioning ourselves at the forefront of industry advancements

0.2 g/kWh

LOW OIL CONSUMPTION

The consumption of lubricating oil does not exceed 0.2 grams per kilowatt-hour.

2 MW = 17 t

Compactness

The best power-to-weight ratio.

2,000 engine hours

Service Interval

Maintenance with minimal equipment downtime.

41.6%

High performance

The efficiency of electricity generation reaches 41.6%, and in comprehensive operation with heat recovery taken into account, it can reach up to 90%.

> MN55

Operating on all types of gas

Electric generator sets operating on natural gas, biogas, associated petroleum gas, and other types of gaseous fuels.

less than 50 kopecks

Operating expenses

OPEX includes expenses for spare parts, labor, and technical fluids.

Advantages

Advantages of Gas-Piston Power Plants

0.2 g/kWh

LOW OIL CONSUMPTION

The consumption of lubricating oil does not exceed 0.2 grams per kilowatt-hour.

2 MW = 17 t

Compactness

The best power-to-weight ratio.

2,000 engine hours

Service Interval

Maintenance with minimal equipment downtime.

41.6%

High performance

The efficiency of electricity generation reaches 41.6%, and in comprehensive operation with heat recovery taken into account, it can reach up to 90%.

> MN55

Operating on all types of gas

Electric generator sets operating on natural gas, biogas, associated petroleum gas, and other types of gaseous fuels.

less than 50 kopecks

Operating expenses

OPEX includes expenses for spare parts, labor, and technical fluids.

Advantages

Advantages of Gas-Piston Power Plants

80x

Carbon footprint

We actively embrace new ideas and technologies, positioning ourselves at the forefront of industry advancements

0.2 g/kWh

LOW OIL CONSUMPTION

The consumption of lubricating oil does not exceed 0.2 grams per kilowatt-hour.

2 MW = 17 t

Compactness

The best power-to-weight ratio.

2,000 engine hours

Service Interval

Maintenance with minimal equipment downtime.

41.6%

High performance

The efficiency of electricity generation reaches 41.6%, and in comprehensive operation with heat recovery taken into account, it can reach up to 90%.

> MN55

Operating on all types of gas

Electric generator sets operating on natural gas, biogas, associated petroleum gas, and other types of gaseous fuels.

less than 50 kopecks

Operating expenses

OPEX includes expenses for spare parts, labor, and technical fluids.

Capabilities of Chinese GPUs

Advantages of containerized installation of gas-based mini-CHP plants

Production time

Manufacturing a gas-piston unit in full factory configuration takes from 4 to 6 months.

Operational convenience

The overall dimensions of the containerized gas-turbine unit — 13.5 x 3.0 meters — allow for easy maintenance.

Noise filtering and suppression

All power plant containers are equipped with a supply and exhaust ventilation system with pre-filtration and noise reduction.

Mass

Chinese power plants have the best specific mass per unit of power.

Monitoring

Remote report on the power plant operations, as well as a list of malfunctions and events in the system.

Localized operator menu

Visualization of equipment operation parameters in Russian.

Capabilities of Chinese GPUs

Advantages of containerized installation of gas-based mini-CHP plants

Production time

Manufacturing a gas-piston unit in full factory configuration takes from 4 to 6 months.

Operational convenience

The overall dimensions of the containerized gas-turbine unit — 13.5 x 3.0 meters — allow for easy maintenance.

Noise filtering and suppression

All power plant containers are equipped with a supply and exhaust ventilation system with pre-filtration and noise reduction.

Mass

Chinese power plants have the best specific mass per unit of power.

Monitoring

Remote report on the power plant operations, as well as a list of malfunctions and events in the system.

Localized operator menu

Visualization of equipment operation parameters in Russian.

Capabilities of Chinese GPUs

Advantages of containerized installation of gas-based mini-CHP plants

Production time

Manufacturing a gas-piston unit in full factory configuration takes from 4 to 6 months.

Operational convenience

The overall dimensions of the containerized gas-turbine unit — 13.5 x 3.0 meters — allow for easy maintenance.

Noise filtering and suppression

All power plant containers are equipped with a supply and exhaust ventilation system with pre-filtration and noise reduction.

Mass

Chinese power plants have the best specific mass per unit of power.

Monitoring

Remote report on the power plant operations, as well as a list of malfunctions and events in the system.

Localized operator menu

Visualization of equipment operation parameters in Russian.

Other Power Plants of Hunan Liyu

Industry Solutions

Questionnaire

Please fill out the form, and we will send you a commercial offer.

Questionnaire

Please fill out the form, and we will send you a commercial offer.

Questionnaire

Please fill out the form, and we will send you a commercial offer.

Questionnaire

Please complete the questionnaire to prepare and receive a commercial offer.

Company Name, Taxpayer Identification Number (TIN)

Contact Phone

Contact e-mail

Contact Person

Priority Mode of Operation

Execution Option

Required electrical power, kW

Business Hours

Heating, Gcal/hr

Hot water supply, Gcal/hour

Hot water supply, Gcal/hour

Generator Voltage

Type of Gas

Gas limits availability

Gas pressure at the site, kPa

The price per 1 kWh of electricity, including capacity surcharge

Price for 1,000 m3 of gas, including transportation

The cost per 1 MW (or 1 Gcal) of heat (the production cost of Gcal from an in-house boiler)

Questionnaire

Please complete the questionnaire to prepare and receive a commercial offer.

Questionnaire

Please complete the questionnaire to prepare and receive a commercial offer.

Company Name, Taxpayer Identification Number (TIN)

Contact Phone

Contact e-mail

Contact Person

Priority Mode of Operation

Execution Option

Required electrical power, kW

Business Hours

Heating, Gcal/hr

Hot water supply, Gcal/hour

Hot water supply, Gcal/hour

Generator Voltage

Type of Gas

Gas limits availability

Gas pressure at the site, kPa

The price per 1 kWh of electricity, including capacity surcharge

Price for 1,000 m3 of gas, including transportation

The cost per 1 MW (or 1 Gcal) of heat (the production cost of Gcal from an in-house boiler)

Create a free website with Framer, the website builder loved by startups, designers and agencies.