Liyu Power LY1600 Gas-Piston Power Plant

1,500 kW

For installation in the machine room

SP TRADE offers to purchase 1500 kW gas piston power plants, which will become a reliable source of electricity for various facilities. Gas engine power plants are used in various industries—from housing and utilities and greenhouses to industrial clusters. These installations are designed for generating electricity and heat to ensure uninterrupted energy supply to enterprises.

Number of cylinders

Number of cylinders

16

16

Electric Power

Electric Power

1,500 kW

1,500 kW

Thermal power

Thermal power

1,670 kW

1,670 kW

Electrical efficiency:

Electrical efficiency:

41.3%

41.3%

Overall Efficiency:

Overall Efficiency:

87.3%

87.3%

Type of gas:

Type of gas:

natural

natural

Dimensions (L x W x H):

Dimensions (L x W x H):

6820/1700/2615 mm

6820/1700/2615 mm

Net weight:

Net weight:

15,000 kg

15,000 kg

Features and Applications of the GPES 1500 kW

A 1500 kW gas piston power plant is the optimal choice for large industrial enterprises, utility companies, and commercial facilities requiring stable power supply. The 1.5 megawatt GPPs can be used both as a primary and backup source of electricity.

The electrical efficiency of the 1500 kW GPP (on natural gas) is 41.3%, with an overall efficiency of 87.5%. The power station operates based on an environmentally friendly and cost-effective gas engine for electricity production, through the ignition of a gas-air mixture. During fuel combustion, mechanical energy is generated. This energy is transferred to a generator, which converts it into electricity.



Advantages of GPP 1500 kW

Advantages of GPP 1500 kW

Advantages of GPP 1500 kW

The main advantages of the 1500 kW gas-piston power plant are the cost of electricity and the availability of an accompanying resource that can also be used—heat. Other benefits include:

Reliability. The 1500 kW GPCS ensures uninterrupted electricity production.

Mobility. The 1.5 MW GPU can be easily integrated into existing networks at the enterprise.

Eco-friendliness. The gas engine is considered more environmentally friendly compared to diesel engines.

SP TRADE provides a warranty of up to 12 months and technical support at all stages—from selection to installation and commissioning. Purchase the equipment or get more information about the 1500 kW gas-piston power plant by calling: +7 985 460 19 97, +7 985 460 11 60.

The main advantages of the 1500 kW gas-piston power plant are the cost of electricity and the availability of an accompanying resource that can also be used—heat. Other benefits include:

Reliability. The 1500 kW GPCS ensures uninterrupted electricity production.

Mobility. The 1.5 MW GPU can be easily integrated into existing networks at the enterprise.

Eco-friendliness. The gas engine is considered more environmentally friendly compared to diesel engines.

SP TRADE provides a warranty of up to 12 months and technical support at all stages—from selection to installation and commissioning. Purchase the equipment or get more information about the 1500 kW gas-piston power plant by calling: +7 985 460 19 97, +7 985 460 11 60.

The main advantages of the 1500 kW gas-piston power plant are the cost of electricity and the availability of an accompanying resource that can also be used—heat. Other benefits include:

Reliability. The 1500 kW GPCS ensures uninterrupted electricity production.

Mobility. The 1.5 MW GPU can be easily integrated into existing networks at the enterprise.

Eco-friendliness. The gas engine is considered more environmentally friendly compared to diesel engines.

SP TRADE provides a warranty of up to 12 months and technical support at all stages—from selection to installation and commissioning. Purchase the equipment or get more information about the 1500 kW gas-piston power plant by calling: +7 985 460 19 97, +7 985 460 11 60.

Liyu Power LY1600

Liyu Power LY1600

Liyu Power LY1600

Liyu Power GPU Model

LY1600 (LY1600GL-T, LY1600GM-T, LY1600GH-T)

Liyu Power GPU Model

LY1600 (LY1600GL-T, LY1600GM-T, LY1600GH-T)

Liyu Power GPU Model

LY1600 (LY1600GL-T, LY1600GM-T, LY1600GH-T)

Engine model

LY16V170-T

Engine model

LY16V170-T

Engine model

LY16V170-T

Electric Power

1,500 kW

Electric Power

1,500 kW

Electric Power

1,500 kW

Thermal power

1,670 kW

Thermal power

1,670 kW

Thermal power

1,670 kW

Electrical Efficiency

41.3%

Electrical Efficiency

41.3%

Electrical Efficiency

41.3%

Overall efficiency

87.3%

Overall efficiency

87.3%

Overall efficiency

87.3%

Voltage

0.4/6.3/10.5 kV

Voltage

0.4/6.3/10.5 kV

Voltage

0.4/6.3/10.5 kV

Fuel consumption at 100%, LHV – 9.3

390 Nm³/h

Fuel consumption at 100%, LHV – 9.3

390 Nm³/h

Fuel consumption at 100%, LHV – 9.3

390 Nm³/h

Type of Fuel

Natural gas (GOST 5542-2014), APG, BIO, landfill gas, etc.

Type of Fuel

Natural gas (GOST 5542-2014), APG, BIO, landfill gas, etc.

Type of Fuel

Natural gas (GOST 5542-2014), APG, BIO, landfill gas, etc.

Specific oil consumption

≤0.2

Specific oil consumption

≤0.2

Specific oil consumption

≤0.2

Service Interval

2,000 m/h

Service Interval

2,000 m/h

Service Interval

2,000 m/h

Service life until major overhaul

64,000 hours

Service life until major overhaul

64,000 hours

Service life until major overhaul

64,000 hours

Dimensions (L x W x H)

6820/1700/2615 mm

Dimensions (L x W x H)

6820/1700/2615 mm

Dimensions (L x W x H)

6820/1700/2615 mm

Net weight

15,000 kg

Net weight

15,000 kg

Net weight

15,000 kg

Additional Technical Specifications

Additional Technical Specifications

Additional Technical Specifications

4-valve individual head for each cylinder.

4-valve individual head for each cylinder.

4-valve individual head for each cylinder.

NOx Emissions: ≤500 mg/Nm³ (2 g/kWh)

NOx Emissions: ≤500 mg/Nm³ (2 g/kWh)

NOx Emissions: ≤500 mg/Nm³ (2 g/kWh)

Two-stage cooling of the gas-air mixture.

Two-stage cooling of the gas-air mixture.

Two-stage cooling of the gas-air mixture.

Easy-to-maintain container design.

Easy-to-maintain container design.

Easy-to-maintain container design.

The positioning of the spark plugs is in the center of the cylinder heads within a cooled sleeve.

The positioning of the spark plugs is in the center of the cylinder heads within a cooled sleeve.

The positioning of the spark plugs is in the center of the cylinder heads within a cooled sleeve.

The content of harmful substances in exhaust gases is regulated by adjusting the temperature in the combustion chamber.

The content of harmful substances in exhaust gases is regulated by adjusting the temperature in the combustion chamber.

The content of harmful substances in exhaust gases is regulated by adjusting the temperature in the combustion chamber.

Question and Answer

Is there technical support available in case of malfunctions with the 1.5 MW GPU?

Is there technical support available in case of malfunctions with the 1.5 MW GPU?

Is there technical support available in case of malfunctions with the 1.5 MW GPU?

Is it possible to use a 1500 kW generator as a backup power source?

Is it possible to use a 1500 kW generator as a backup power source?

Is it possible to use a 1500 kW generator as a backup power source?

Is there customer support?

Is there customer support?

Is there customer support?

Product Brochure

Take advantage of Liyu gas piston units and achieve: reduced costs for electricity and thermal energy, ensuring the energy independence of the enterprise.

Product Brochure

Take advantage of Liyu gas piston units and achieve: reduced costs for electricity and thermal energy, ensuring the energy independence of the enterprise.

Product Brochure

Take advantage of Liyu gas piston units and achieve: reduced costs for electricity and thermal energy, ensuring the energy independence of the enterprise.

Advantages

Advantages of Gas-Piston Power Plants

80x

Carbon footprint

We actively embrace new ideas and technologies, positioning ourselves at the forefront of industry advancements

0.2 g/kWh

LOW OIL CONSUMPTION

The consumption of lubricating oil does not exceed 0.2 grams per kilowatt-hour.

2 MW = 17 t

Compactness

The best power-to-weight ratio.

2,000 engine hours

Service Interval

Maintenance with minimal equipment downtime.

41.6%

High performance

The efficiency of electricity generation reaches 41.6%, and in comprehensive operation with heat recovery taken into account, it can reach up to 90%.

> MN55

Operating on all types of gas

Electric generator sets operating on natural gas, biogas, associated petroleum gas, and other types of gaseous fuels.

less than 50 kopecks

Operating expenses

OPEX includes expenses for spare parts, labor, and technical fluids.

Advantages

Advantages of Gas-Piston Power Plants

0.2 g/kWh

LOW OIL CONSUMPTION

The consumption of lubricating oil does not exceed 0.2 grams per kilowatt-hour.

2 MW = 17 t

Compactness

The best power-to-weight ratio.

2,000 engine hours

Service Interval

Maintenance with minimal equipment downtime.

41.6%

High performance

The efficiency of electricity generation reaches 41.6%, and in comprehensive operation with heat recovery taken into account, it can reach up to 90%.

> MN55

Operating on all types of gas

Electric generator sets operating on natural gas, biogas, associated petroleum gas, and other types of gaseous fuels.

less than 50 kopecks

Operating expenses

OPEX includes expenses for spare parts, labor, and technical fluids.

Advantages

Advantages of Gas-Piston Power Plants

80x

Carbon footprint

We actively embrace new ideas and technologies, positioning ourselves at the forefront of industry advancements

0.2 g/kWh

LOW OIL CONSUMPTION

The consumption of lubricating oil does not exceed 0.2 grams per kilowatt-hour.

2 MW = 17 t

Compactness

The best power-to-weight ratio.

2,000 engine hours

Service Interval

Maintenance with minimal equipment downtime.

41.6%

High performance

The efficiency of electricity generation reaches 41.6%, and in comprehensive operation with heat recovery taken into account, it can reach up to 90%.

> MN55

Operating on all types of gas

Electric generator sets operating on natural gas, biogas, associated petroleum gas, and other types of gaseous fuels.

less than 50 kopecks

Operating expenses

OPEX includes expenses for spare parts, labor, and technical fluids.

Capabilities of Chinese GPUs

Advantages of containerized installation of gas-based mini-CHP plants

Production time

Manufacturing a gas-piston unit in full factory configuration takes from 4 to 6 months.

Operational convenience

The overall dimensions of the containerized gas-turbine unit — 13.5 x 3.0 meters — allow for easy maintenance.

Noise filtering and suppression

All power plant containers are equipped with a supply and exhaust ventilation system with pre-filtration and noise reduction.

Mass

Chinese power plants have the best specific mass per unit of power.

Monitoring

Remote report on the power plant operations, as well as a list of malfunctions and events in the system.

Localized operator menu

Visualization of equipment operation parameters in Russian.

Capabilities of Chinese GPUs

Advantages of containerized installation of gas-based mini-CHP plants

Production time

Manufacturing a gas-piston unit in full factory configuration takes from 4 to 6 months.

Operational convenience

The overall dimensions of the containerized gas-turbine unit — 13.5 x 3.0 meters — allow for easy maintenance.

Noise filtering and suppression

All power plant containers are equipped with a supply and exhaust ventilation system with pre-filtration and noise reduction.

Mass

Chinese power plants have the best specific mass per unit of power.

Monitoring

Remote report on the power plant operations, as well as a list of malfunctions and events in the system.

Localized operator menu

Visualization of equipment operation parameters in Russian.

Capabilities of Chinese GPUs

Advantages of containerized installation of gas-based mini-CHP plants

Production time

Manufacturing a gas-piston unit in full factory configuration takes from 4 to 6 months.

Operational convenience

The overall dimensions of the containerized gas-turbine unit — 13.5 x 3.0 meters — allow for easy maintenance.

Noise filtering and suppression

All power plant containers are equipped with a supply and exhaust ventilation system with pre-filtration and noise reduction.

Mass

Chinese power plants have the best specific mass per unit of power.

Monitoring

Remote report on the power plant operations, as well as a list of malfunctions and events in the system.

Localized operator menu

Visualization of equipment operation parameters in Russian.

Other Power Plants of Hunan Liyu

Industry Solutions

Questionnaire

Please fill out the form, and we will send you a commercial offer.

Questionnaire

Please fill out the form, and we will send you a commercial offer.

Questionnaire

Please fill out the form, and we will send you a commercial offer.

Questionnaire

Please complete the questionnaire to prepare and receive a commercial offer.

Company Name, Taxpayer Identification Number (TIN)

Contact Phone

Contact e-mail

Contact Person

Priority Mode of Operation

Execution Option

Required electrical power, kW

Business Hours

Heating, Gcal/hr

Hot water supply, Gcal/hour

Hot water supply, Gcal/hour

Generator Voltage

Type of Gas

Gas limits availability

Gas pressure at the site, kPa

The price per 1 kWh of electricity, including capacity surcharge

Price for 1,000 m3 of gas, including transportation

The cost per 1 MW (or 1 Gcal) of heat (the production cost of Gcal from an in-house boiler)

Questionnaire

Please complete the questionnaire to prepare and receive a commercial offer.

Questionnaire

Please complete the questionnaire to prepare and receive a commercial offer.

Company Name, Taxpayer Identification Number (TIN)

Contact Phone

Contact e-mail

Contact Person

Priority Mode of Operation

Execution Option

Required electrical power, kW

Business Hours

Heating, Gcal/hr

Hot water supply, Gcal/hour

Hot water supply, Gcal/hour

Generator Voltage

Type of Gas

Gas limits availability

Gas pressure at the site, kPa

The price per 1 kWh of electricity, including capacity surcharge

Price for 1,000 m3 of gas, including transportation

The cost per 1 MW (or 1 Gcal) of heat (the production cost of Gcal from an in-house boiler)

Create a free website with Framer, the website builder loved by startups, designers and agencies.